Cool Rooms
We, Heating and cooling engineers, have designed cool rooms for the Food industry for more than 10 years
Cool Rooms
Click to book an appointment online or organise a call back.
Cool Rooms
Key Features
- Covered stainless steel reinforced floors with an antiskid tread pattern
- Large door with the replaceable press-in gasket
- Side mounted self-contained cooling unit can be mounted on any wall
- Cooling units rated at 43deg C ambient temperature
- Stainless steel exterior skirting
- The interior light supplied fix into the position
- Cool room temp 0deg to +8deg
- Freezer room temp -10deg to -25deg
Advantages of using Heating and Cooling Engineers.
High-quality Insulated Panel
We use quality Insulated panels minimum of 100mm thick, modular construction incorporating wall and ceiling panels, and be of “woodless” type construction. Committees shall consist of insulation sandwiched between interior and exterior metal skin. Panel edges to have tongues and grooves that cam-lock together, assuring an airtight vapor-proof joint. All panel insulation we use shall be density polyurethane foam insulation expanded with “Ozone-Safe” and Australian standard of AS 1530.3 equivalent to American ASTM E84.
We use upon request FM 4880 (Factory Mutual) Approval Global Standard for Class 1 Fire Rating of Insulated Panels, Interior Finish Materials or Coatings and Exteriors Wall Systems evaluates a panel’s ability to contribute to a fire in a variety of different ways through a tiny corner test or larger scale corner test.
Solid Door construction
Door construction shall match the insulated panels. Each entrance is to have a clear opening of 800 mm wide by 2000mm H. Doors shall be flush mounted, in-fitting, and have a replaceable magnetic gasket on three sides and an adjustable neoprene gasket at the sill. Door hardware shall include three (3) heavy-duty hinges, a heavy door closed, and a latch/release. In addition, each door shall be equipped with a 400 x400 heated viewing window.
Floor panels or Slab heating – a quality design
Suppose the Cool rooms on a concrete slab-on-grade will require a floor heating and insulating system underside floor panels. If an insulated floor panel is to be provided, the floor panels shall be capable of withstanding loads. We might have to use checker plates for an anti-slip mechanism and close openings between insulated panels and building walls. Seal all joints, doors, piping, electrical, and ductwork penetrations (regardless of trade). Seal both sides of penetrations (if possible) and inside the electrical conduit once wires have been pulled.
Installation expertise
Install all cold rooms by the manufacturer’s written instructions and reviewed shop drawings. Install sheet metal closure trim that matches the insulated panel finish between all building walls and insulated panels. Verify placement of all exposed piping and conduit with the Owner’s Representative before installation. Install interconnecting accessories by the manufacturer’s written recommendations and locate them for ease of servicing. Provide piping with good engineering practice. Suction line insulation shall be sized and installed to prevent condensation. We provide individual traps for condensate drains. Pre-test all equipment operation and performance of each walk-in, and make all adjustments and repairs as required. H Clean all rooms inside and out, including the roof of each walk-in. Remove all debris and marks. All electrical components utilized within each walk-in shall work and provide the appropriate circuits to each condensing unit and a pull box above each cold room. All interconnecting and control wiring is to be the walk-in supplier. A fused disconnect is to be provided at each condensing. Exposed conduit inside the cold room shall be kept to a very minimum.
Control
All our controls must have compressor control with pump down capability, controlling condenser fan, and variable speed evaporator fan motor. Better sensing with up to 4 temperature probes, intelligent logic based on average measurement of two temperature sensors plus humidity sensor or controller USB support and Configuration after commissioning, you can save
parameters on the USB key for your next cold room. also, a HACCP standard means – temperature and alarm data logging, and the user can save data easily to a USB key
Key Features
- Covered stainless steel reinforced floors with an antiskid tread pattern
- Large door with the replaceable press in gasket
- Side mounted self-contained cooling unit can be mounted on any wall
- Cooling units rated at 43deg C ambient temperature
- Stainless steel exterior skirting
- The interior light supplied just fix into the position
- Cool room temp 0deg to +8deg
- Freezer room temp -10deg to -25deg
Display Fridges/ Freezers – Melbourne
- Deli / Butchery
- Cake
- Bakery
- Open Face Merchandiser
- Counter Models
- Sushi Displays
What Our Customers Are Saying
Amazing! Came out on a Saturday, during a lockdown, and managed to fix our ducted heating unit which needed a new igniter and board both of which they had in their truck! Was all done in 30mins. I was expecting a long cold week waiting for parts in a house that had dropped to 14deg. Really reasonable and helpful. Strongly recommend.